Starlight

A polarisation measured faster than the air changes

Polarisation is a difference between two brightnesses, and the brightness of a star seen through the air changes by a per cent from one millisecond to the next. Measure the two one after the other and the air's flicker becomes a false polarisation a hundred times larger than the signals worth having. The cure is to switch between them faster than the air can change, or to measure both at once and then swap them — turning a calibration problem into a differential one.

Assumes Polarimetry, Seeing and Photon noise.

A photometer throws away the direction of the light it counts, and a polarimeter recovers it by counting twice: once through an analyser that passes light vibrating one way, once through one that passes light vibrating at right angles. The Stokes parameter QQ is the normalised difference,

q=QI=I∥−I⊥I∥+I⊥,q = \frac{Q}{I} = \frac{I_\parallel - I_\perp}{I_\parallel + I_\perp},

and UU is the same thing at forty-five degrees. For most stars qq and uu are fractions of a per cent; for the polarisation of a planet’s reflected light seen against its star, or of starlight scattered by a dust disc, they are parts per million.

Measuring a difference that small between two numbers that are each a whole star’s light is a problem of a familiar shape: the precision depends far less on how well each number is measured than on whether they are measured under the same conditions. The instrument’s own polarisation is one source of difference between the two conditions. This essay is about the other, which is the air.

How fast to switch. The rms false polarisation left by a 1 per cent rms brightness fluctuation, against the modulation frequency, both on logarithmic scales, for fluctuations whose spectrum turns down at 5, 20, 100 Hz. Below the turnover the false signal is the whole fluctuation, about 0.7 per cent; above it, it falls steeply as the pairs are taken faster than the air changes. To reach a part in ten thousand (dashed) — the precision at which stellar and planetary polarisation becomes interesting — the switching must run at 3,311 Hz, 13,183 Hz, 66,069 Hz respectively: switching at hertz is useless, and a single beam needs kilohertz or more.
Fig. 1 The false polarisation left by a one per cent rms flicker in a star’s brightness, against how fast the polarimeter switches between its two states, on logarithmic scales, for flicker whose spectrum turns down at 5, 20 and 100 Hz. Switching slowly, the false signal is the whole flicker, 0.7 per cent. Switching faster than the air changes, it falls steeply. To reach a part in ten thousand (dashed), a single-beam polarimeter must switch at three, thirteen or sixty-six kilohertz respectively.

Two parameters, and why the errors add a bias

A polarisation has a size and a direction, and the two Stokes parameters qq and uu carry both: the degree of polarisation is the length of the vector (q,u)(q, u) and the angle of polarisation on the sky is half its direction in that plane. Every measurement of each comes with an error, and the errors of a careful instrument are independent and equal in the two parameters, so a measurement is a point scattered around the true one in the (q,u)(q, u) plane.

A position angle to 1.7° and a polarisation that is biased upwards. The Stokes plane, with 260 simulated measurements of one star at a true polarisation of 0.6 per cent and a position angle of 62°, each Stokes parameter carrying an independent error of 0.35 per cent. The polarisation is the length of the vector and the position angle is half its azimuth — which is why a rotation of 180° in this plane is a rotation of 90° on the sky, and why polarisation has no sign. Averaging the two components recovers 60.3° against the true 62°. But averaging the lengths gives 0.686 per cent against a true 0.6: a length cannot be negative, so noise can only push it up, and the excess here is 0.112 against the large-signal expectation σ²/2p = 0.102. At zero true polarisation the same effect returns 0.44 per cent from a star that has none, which is the reason a polarimetric detection is quoted in σ and almost never in per cent alone.
Fig. 2 The plane of the two Stokes parameters, with many simulated measurements of one star whose true polarisation is 0.6 per cent, each parameter carrying an independent error of 0.35 per cent. The degree of polarisation is the length of each point’s vector from the origin and the position angle is half its direction. Averaging the two parameters recovers the true direction; averaging the lengths does not recover the true degree, because a length cannot be negative and noise always adds to it.

The figure carries a warning that matters more as the polarisation gets smaller. A length is never negative, so noise in qq and uu always lengthens the measured vector on average; a star with no polarisation at all, measured with errors of a part in ten thousand, appears polarised at a part in ten thousand. When the polarisation sought is comparable to the errors — which is the regime of every measurement at the frontier — the degree must be corrected for this bias, and the correction depends on knowing the errors well. A systematic error that is not included in the error estimate is not only an error in the result: it biases the degree upward, and it does so in a way that looks like signal.

That is why the false polarisations of this essay matter even when they are random from one measurement to the next. Random false signals average down over many measurements, but they inflate the scatter in the (q,u)(q, u) plane, and if the inflated scatter is not recognised, the bias correction is too small and a polarisation is reported that is not there.

A difference taken at two moments

The simplest polarimeter has one detector and a rotating analyser, or a fixed analyser with a modulator in front of it that switches which polarisation the analyser passes. It measures I∥I_\parallel, then I⊥I_\perp, then I∥I_\parallel again, and forms the difference from each pair. If the star’s brightness were constant, the pairs would differ only by the polarisation.

The star’s brightness is not constant. Seen through the turbulent atmosphere, it twinkles — scintillation from turbulence high in the air focusing and defocusing the wavefront — and on a large telescope the twinkling of a bright star is about a per cent rms, with most of its power at frequencies of tens to hundreds of hertz. Guiding errors and the image wandering across a slit add slower fluctuations of their own. A brightness change between the two halves of a pair is indistinguishable from polarisation: if the star brightens by a per cent while the polarimeter switches from one state to the other, the measured qq is half a per cent.

Brightness that changes between two measurements. Half a second of a star's brightness as the air above the telescope changes, normalised to its mean, with a fluctuation of 1 per cent rms spread over frequencies up to about 20 Hz and falling faster above. A polarimeter that alternates between two states 10 times a second takes the pairs marked (dots), and every difference between a pair's two brightnesses masquerades as polarisation: 0.6 per cent rms here. Alternating 1000 times a second, each pair is taken in half a millisecond, the brightness barely changes within it, and the false polarisation falls to 0.076 per cent — better, and still far from the part in ten thousand or better that stellar polarimetry needs.
Fig. 3 Half a second of a star’s brightness through the air, normalised to its mean, with a one per cent rms flicker spread over frequencies up to about 20 Hz. A polarimeter alternating between two states ten times a second takes the pairs marked — first state blue, second orange — and every difference between a pair’s brightnesses masquerades as polarisation, 0.6 per cent rms here. Alternating a thousand times a second the false polarisation falls tenfold — better, and still far from the part in ten thousand that stellar polarimetry needs.

The false signal is set by how much the brightness changes in half a modulation period. If the brightness’s fluctuations have a spectrum S(f)S(f), the variance of the change over an interval Δt\Delta t is

⟨(I(t+Δt)−I(t))2⟩=2∫S(f) [1−cos⁡2πfΔt]df,\langle (I(t+\Delta t) - I(t))^2 \rangle = 2\int S(f)\,\left[1 - \cos 2\pi f\Delta t\right]df,

which is small only when Δt\Delta t is short compared with the period of every frequency that carries significant power. Switching ten times a second leaves the whole flicker in; switching a thousand times a second removes the slow part and leaves the fast part, because the twinkling’s spectrum falls off above its turnover only as a modest power of the frequency. To bring the false polarisation to a part in ten thousand, the first figure says, the switching must run at kilohertz to tens of kilohertz.

Switching at tens of kilohertz

No mechanical device rotates an analyser at tens of kilohertz. The instruments that do it use a photoelastic modulator — a block of glass squeezed periodically by a piezoelectric transducer at its own resonant frequency, so that it becomes birefringent and unbirefringent tens of thousands of times a second, swinging the polarisation that reaches the analyser back and forth. The detector must keep up: either a photomultiplier or avalanche photodiode whose counts are separated into bins synchronised with the modulator, or a CCD whose charge is shifted back and forth under a mask in step with it, accumulating the two states in alternate rows.

The second scheme, built in Zurich for solar polarimetry, became the model for imaging polarimeters at tens of kilohertz. A detector that shifts its charge in step with a modulator effectively takes two images interleaved in time at microsecond intervals, so that whatever the air does is common to both, and then reads them out after many thousands of cycles. The same principle at slightly lower speeds, with ferroelectric liquid-crystal modulators switching at hundreds of hertz to a kilohertz and fast photon-counting detectors, reached parts per million on the brightest stars.

Two beams at once

There is another way to remove the air’s flicker, and it costs no speed: measure both polarisations simultaneously. A Wollaston prism splits the light into two beams polarised at right angles and sends them to two parts of a detector. Each exposure records I∥I_\parallel and I⊥I_\perp through the same air at the same moment, and the normalised difference is untouched by scintillation.

It is touched by something else. The two beams fall on different pixels, pass through slightly different optics and are recorded with different efficiencies, and their ratio of gains is never exactly one. A gain mismatch of a per cent produces a false qq of half a per cent in every exposure — the same size as the scintillation error the beam-splitter was introduced to remove.

Two beams, and swapping them. The false polarisation left by a mismatch between the gains of the two detectors (or the two halves of one detector) that record the orthogonal states simultaneously, against the size of the mismatch. Measured once, the false signal is half the mismatch: a one per cent difference in gain is half a per cent of false polarisation (orange). Exchanging the two beams with a half-wave retarder and taking the ratio of the two exposures' ratios cancels the gains exactly, and also cancels any change of transparency between the exposures — here 1 per cent. What remains is whatever changes between the exposures in one beam only: if the gain mismatch itself drifts by a thousandth of its size, the residual (blue) is about 2.5 parts in ten thousand of the mismatch — a one per cent gain difference leaves 2.5 parts in a million of false polarisation, a factor of 2,000 better than a single exposure.
Fig. 4 The false polarisation from a mismatch between the gains of the two beams of a dual-beam polarimeter, against the size of the mismatch. Measured once, the false signal is half the mismatch (orange). Exchanging the two beams with a half-wave plate between two exposures and taking the ratio of the two ratios cancels the gains exactly, and with them any change of transparency between the exposures. What remains is whatever changes in one beam only: if the mismatch itself drifts by a thousandth between exposures, a one per cent gain difference leaves 2.5 parts in a million (blue).

The remedy is to exchange the beams. A half-wave plate in front of the beam-splitter, rotated by forty-five degrees between two exposures, swaps which polarisation goes to which beam. In the first exposure beam A carries I∥I_\parallel and beam B carries I⊥I_\perp; in the second, A carries I⊥I_\perp and B carries I∥I_\parallel. The ratio of the two beams in each exposure contains the gain ratio once and the polarisation once; dividing the first exposure’s ratio by the second’s cancels the gain ratio and doubles the polarisation. The transparency of the air, which may differ between the two exposures, cancels too, because it multiplies both beams in each exposure equally.

The method, the double ratio or double difference, is what most dual-beam polarimeters on large telescopes do. It needs two exposures per Stokes parameter, and in practice four, at four angles of the half-wave plate, so that residual errors that depend on the plate’s angle also average out. What it cannot cancel is any change between the exposures that affects one beam and not the other: a gain that drifts, a flat field that shifts, a ghost that moves. Those are second-order — a drift in the mismatch rather than the mismatch itself — and the figure shows the size: a per cent of gain mismatch drifting by a thousandth of itself leaves a few parts in a million.

The Sun, where the image itself moves

Solar polarimetry faces the same problem in a sharper form. Its target is not a point but an image of the solar surface, covered in granulation — bright cells and dark lanes a few hundred kilometres across, changing in minutes — and the polarisation it seeks is the faint circular and linear signal of magnetic fields in spectral lines, often a fraction of a per cent of the line’s depth.

The air does not only make the Sun’s image flicker; it makes the image move. Every few milliseconds the image shifts by a fraction of an arcsecond, and a pixel that was looking at a bright granule finds itself looking at a dark lane. If that happens between the two states of a modulation cycle, the difference in brightness is not a per cent but tens of per cent, and the false polarisation follows. Solar polarimeters therefore combine fast modulation with dual beams and with adaptive optics that hold the image still, and they have been among the drivers of fast detectors and modulators: the kilohertz modulation schemes were developed for the Sun before they were used on stars.

The same structure appears in space, where there is no air but the spacecraft jitters. A solar spectropolarimeter on a satellite, freed from seeing, reached precisions that ground instruments could not, and its residual errors came from the spacecraft’s pointing — the same image motion, from a different source.

What each scheme costs in photons

Every scheme has a price, and it is paid in light.

A single-beam polarimeter throws away half the light at its analyser in each state. A fast modulator with a photoelastic block does not spend equal time in the two pure states — its retardance swings sinusoidally — and its efficiency at isolating each Stokes parameter is below one, typically about seventy per cent, so the noise on the measured polarisation is larger than the photon count alone would give. A dual-beam polarimeter keeps both polarisations, but it needs at least two exposures per parameter for the beam exchange, and four for the most robust schemes, so each exposure must be correspondingly shorter.

The trade is between the efficiency with which photons are converted into polarisation measurements and the size of the systematic floor. For faint sources, where photons are scarce and the floor is far below the noise, efficiency wins, and simple schemes are preferred. For bright sources, where photons are plentiful and the floor is everything, the most robust scheme wins even if it wastes half the light. The last figure is the decision chart: where the photon-noise curve meets an instrument’s floor is the brightness at which its designers should stop caring about efficiency.

The surprising part: two instruments, one idea

Fast modulation and beam exchange look like opposite strategies. One measures the two states at nearly the same time on the same detector; the other measures them at exactly the same time on different detectors and then repeats with the detectors swapped. They are the same idea seen from two sides.

Each converts an absolute measurement into a differential one. A single-beam, fast-modulated polarimeter compares two states on the same pixels, so pixel gains cancel; it needs speed so that the air does not change between them. A dual-beam, exchanged polarimeter compares two states at the same moment, so the air cancels; it needs the exchange so that pixel gains cancel too. Each removes one source of difference by symmetry and the other by repetition, and the most precise instruments combine both — two beams, fast modulation, and periodic exchange — so that every systematic error has at least one symmetry working against it.

The same logic governs adaptive optics, which must correct the wavefront faster than the air distorts it, and differential photometry, which measures a target against comparison stars through the same air at the same time. Every precise measurement through the atmosphere is in the end a race against the air or a comparison made inside the same patch of it.

Where photons stop helping

Where photons stop helping. The precision of a polarisation measurement against integration time, on logarithmic axes, for a bright star giving a hundred million detected photons a second: photon noise alone (black) falls as the square root of the time; a residual systematic error of 10⁻⁴, 10⁻⁵, 10⁻⁶ does not fall at all. The total is set by whichever is larger, and the photon noise reaches each floor after 1 second, 2 minutes, 2.8 hours. Collecting more light beyond that buys nothing; only a better modulation scheme moves the floor.
Fig. 5 The precision of a polarisation measurement against integration time, for a bright star giving a hundred million detected photons a second: photon noise alone (dashed) falls as the square root of the time, and a residual systematic error of 10−410^{-4}, 10−510^{-5} or 10−610^{-6} does not fall at all. The photon noise reaches each floor after about a second, two minutes and three hours. Beyond that, collecting more light buys nothing; only a better scheme lowers the floor.

For faint sources, photon noise sets the precision, and the systematic errors in this essay hardly matter. For bright stars the situation is reversed. A star bright enough to deliver a hundred million photons a second reaches a precision of a part in ten thousand in a second, and its measurement from then on is limited by whatever systematic floor the instrument has. Halving the floor is worth a quadrupling of the observing time; reducing it tenfold is worth a hundredfold.

That is why precise polarimetry is an instrument-design problem rather than a telescope-size problem. A larger telescope collects photons faster, which matters only up to the floor; below it, a modest telescope with a better modulation scheme beats a giant one with a worse. Some of the most precise stellar polarimetry has been done on telescopes of a few metres, with instruments whose design was entirely about systematic errors, reaching parts per million on bright stars — precision that made the polarisation of starlight reflected by a hot planet a measurable quantity in principle, although the detections claimed at that level have not survived re-examination.

Checking the zero

A differential scheme removes errors that are different between the two states; it cannot tell whether the zero point of the whole measurement is right. For that, a polarimeter observes stars known to be unpolarised — nearby stars with little interstellar dust in front of them and no circumstellar material — and stars known to be polarised by a well-measured amount. The first set the zero, the second the scale and the angle.

The standards are themselves measurements, and at the frontier they run out. A nearby star is unpolarised to the precision with which it has been measured, which for the best-studied is a few parts in a million; below that, its own magnetic activity, the slight asymmetry of its rapidly rotating surface, and the dust grains of the local interstellar medium all polarise its light by amounts nobody has catalogued. An instrument whose floor is below its standards’ precision cannot verify its own zero point, and its results become a statement about the difference between targets rather than about any one of them.

That is a familiar limit in a new place. Every instrument that measures something to a precision better than any reference eventually has to be checked against itself — by observing the same target at different orientations of the telescope, by rotating the whole polarimeter, by measuring in different seasons — and its results are trusted in proportion to how many independent ways it has found to fail and has not.

What the figures assume

The flicker spectrum is a single shape. A real star’s brightness through the air has a spectrum set by the turbulence profile, the wind speed at each height, the telescope’s aperture and the guiding; it is flat at low frequency and falls as some power of the frequency above a turnover that ranges from a few hertz to a few hundred. The required modulation frequencies drawn here move with the turnover and the slope.

The flicker is the only error in the single-beam figures. Real fast modulators have their own systematic errors — the modulator’s retardance varies with temperature and wavelength, the demodulation timing must be exact, and the detector’s response to rapidly alternating light must be linear — and their floors are set by those once the air is frozen.

The gain drift is a single number. The exchanged-beam residual depends on how the gains of the two beams change between exposures, which depends on the detector’s temperature, the flat field’s stability and the illumination’s position on the detector. A thousandth is plausible for a well-controlled instrument and optimistic for some.

Instrumental polarisation is not included. Everything here is about the difference between two measurements; the polarisation the telescope itself adds to the light before it reaches the polarimeter is a separate, additive error, corrected by observing unpolarised standard stars, and it often sets the true floor for absolute measurements.

Still open: the floor below a part in a million

The polarisation that would be most valuable to measure is the smallest. Starlight reflected by an exoplanet is polarised by scattering in the planet’s atmosphere, and the polarisation of the combined light of star and planet varies with the planet’s orbit at a level of parts in ten million for the most favourable known systems. Measuring it from the ground would reveal the scattering particles in the atmosphere — clouds, hazes, the Rayleigh scattering of a clear sky — without separating the planet’s light from the star’s at all.

Reaching that level needs a systematic floor ten times lower than the best instruments have achieved. The candidates for the dominant remaining error are the polarisation of the telescope itself, which drifts as the telescope tracks and is calibrated only to the precision of the standard stars; the residual non-common effects between beams; and the polarisation of the star itself, which for an active star varies with its own magnetic spots and faculae. Which of these sets the floor, and whether it can be pushed below a part in ten million, is what the next generation of polarimeters is designed to find out.

About the same objects

Not linked from either essay — found by the objects both name.

What links here

Essays that link to this one from their own argument.

The objects this essay names

Each one links to every other essay that touches it.

Differential measurementDual beam polarimetryHalf-wave platePhoton noisePolarimetryPolarisation modulationScintillationStokes parametersSystematic error